Safety alerts
 

Notification procedure

The Association has drafted two procedures whereby safety alerts or other notifiable events may be brought to the attention of other members and the general public so that remedial action may be quickly taken.
 

Public notification of safety alerts or other matters

Authorised communications may be made to AEA ONLY through a member of AEA's Executive Committee, giving brief details of the nature of the problem and a contact name and phone number., with the request that those details be published on the web site or referred to the Technical Committee for investigation and issue of a report. Click here for the notification form.

All such communications are to be lodged in writing and ONLY through a member of AEA's Executive Committee.

The following events are notified for information of members.

Safety Alert from Schindler

NOTE: You will need Adobe Acrobat Reader to view the relevant documents.


SAFETY ALERT REGARDING
 
W200/W250 GEARBOXES

Serial numbers
 
Below 11225

To be especially noted by
 
Maintenance contractors
Strong recommendations from Schindler
1.That the ultrasonic tests (click
here to download) are carried out.

2. That the latest maintenance instructions*  which apply to all W200 and W250 gearboxes, regardless of serial number, are implemented.
 

Further information
Schindler can provide a quotation to carry out the work described in recommendation 2 above.

NOTE * For the time being, please obtain a copy of the maintenance instructions from Schindler. We will place a PDF on the web as soon as possible.
 

Authorised by
John F Bundy
General Manager
Schindler Lifts Australia Pty Ltd
 

Address
 
52-54 O'Dea Avenue Waterloo NSW 2017

Telephone
 
+61 2 9931 9900

Fax
 
+61 2 9931 9995

Web
 
www.Schindler.com

Date of posting: 6 July 2006.

 

Schindler Lifts Australia Pty. Ltd.

ABN 19 005 838 773

52-54 O’Dea Avenue

Waterloo NSW 2017

Australia

Tel. +02 9931 9900

Fax +02 9931 9945

www.au.schindler.com

P O Box 7153

Alexandria NSW 2015

Australia

Subject Safety Alert - Bronze rim of crown wheel in W200/W250 gears

Installation: (Nr, Building Address,…)

Dear Sir / Madam

The lift/s identified above were originally installed with a Schindler manufactured gearbox

referred to as model W200 or W250. During its lifetime, the gear set used in this gearbox is

subject to measurable wear & tear, which may require the replacement of the gear set before

it is substantially weakened by the loss of material.

In addition, the gear set may be exposed to extraordinary shocks in it’s lifetime (such as when

full load safety gear tests are performed), and over a long period of time, symptoms of fatigue

may occur. This may lead in isolated cases to the bronze material of the crown wheel rim in

the gearbox not withstanding the loading. According to experience so far, it can be assumed

the majority of installations do not yet show symptoms of fatigue. However, with continued

operation after repeated severe impacts, deterioration in the life of the gear set is possible,

particularly where installations are more than ten years old.

As a preventive measure, Schindler performs ultrasonic tests of the bronze rim of the gears

concerned in order to identify this risk. Should the wear continue undetected, it could result in

a rupture of the bronze rim, leading to uncontrolled movement of the lift car, which may in turn

lead to serious injuries.

Schindler Lifts Australia Pty. Ltd.

Head Office

Page 2 of 2

responsive people, smart products

Schindler Lifts Australia Pty. Ltd.

ABN 19 005 838 773

52-54 O’Dea Avenue

Waterloo NSW 2017

Australia

Tel. +02 9931 9900

Fax +02 9931 9945

www.au.schindler.com

P O Box 7153

Alexandria NSW 2015

Australia

This testing is conducted on all relevant equipment maintained by Schindler. However, as we

do not maintain your equipment we recommend that you consider our offer in regard to

minimising your risk.

Schindler, as original equipment manufacturer, strongly recommends performing ultrasonic

tests of the crown wheel bronze rim of such installations. Upon your request, Schindler will

perform this measurement at a flat fee of $1,500 per gear set.

If the ultrasonic test shows irregularities in the bronze material, the gear set must be replaced.

If you have any questions regarding this communication, please contact Mr Robert Roseby at

(02) 9931 9900.

Yours sincerely

Schindler Lifts Australia Pty. Ltd.

John Bundy

General Manager, Existing Installations



 

1. Product Alert: Johns & Waygood "Special Home Unit" (SHU) Machine Gearbox

Notified by Otis Elevator Co Pty Ltd, 5 June 2001.

Contact: John Wagschall, 02.9827.3600

 

2. Schindler Gears W200 & W250

Notified by Schindler Lifts Australia, 24 August 2001.

Contact: Darrin Corrigan, 02.9931.9900

 

3. Safety Alert: Otis Machine Type 10ATL

Notified by Otis Elevator Co Pty Ltd, 2 April 2001

Contact: John Wagschall, 02.9827.3600

 

4. E200 Brake shoe pin.

Notified by Kone Elevators Australia Pty Ltd, 3 August 2001.

Contact: Trevor Young, 02.9577.7000

 

Date of posting: 19 March 2007

 

 

 

Safety Alerts

 


Copyright © Australian Elevator Association Ltd 2004

Site by  Australian Elevator Association Ltd


1. Expressly disclaims all and any liability to any person whatsoever in respect of anything done by any person in reliance, whether in whole or in part, on this web site; and

2. Makes no representations as to the currency of information in this web site.